Customization: | Available |
---|---|
Type: | Ventilator |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical specifications | |
Dimension (L*W*H) | 404mm*297mm*576mm(main unit) 538mm*495mm*1391mm(with trolley) |
Weight | Approximately 21.0kg(main unit),approximately <45.3kg(with trolley) |
Ventilation specifications | |
Patient type | Adult, Pediatric, Neonatal |
Invasive ventilation mode | VC-ACV, PC-ACV, PVC-ACV, VC-SIMV, PC-SIMV, PVC-SIMV, PC-Dual PAP, PC-APRY, CPAP/PSV, CPAP-VG, Apnea Ventilation |
Non-invasive ventilation mode | PC-ACV, PVC-ACV, PC-SIMV, PVC-SIMV, PC-Dual PAP, PC-Dual PAP, PC-APRY, CPAP/PSV, CPAP-VG, Apnea Ventilation |
RR spon | 0-250 bpm |
FiO2 Cal | 21-100 VoL.% |
FiO2 Measu | 21-100 VoL.% |
Rlung | 5-300 cmH2O/L/S |
Cdynamic | 0.5-100ml/cmH2O |
RSBI | 0-10000 bpm/min/L |
PTP | 0-10 cmH2O.s |
Controlled parameters | |
FiO2 | 21-100% |
VT (Tidal Volume) | 100-2000ml (Adult), 20-400ml (Pedoatric),5-200ml(Neonatal) |
Pinsp | (PEEP+5)-90 cmH2O |
Phigh | (Plow+5)-80 cmH2O |
Plow | 0-40 cmH2O |
Psupp | 0-80 cmH2O |
PEEP | 0-50 cmH2O |
FiO2 | 21-100% |
Rate | 1-100bpm |
I:E | 4:1-1:10 |
Tinsp | 0.3-12s |
Texp | 0.3-12s |
Tpause | OFF, 5-60% |
Thigh | 0.3-30s |
Tlow | 0.3-30s |
Trigger | Pressure: off, -1 ~-10 cmH2O Flow: OFF, 1~15L/min |
Tslope | 0-2s |
Exp% | OFF, 5-95% |
Controlled parameters(O2 therapy) | |
Continuous flow | 2-50L/min |
O2 concentration | 21-100% |
Pmax | 10-95 cmH2O |
Parameter monitoring accuracy | |
Ppeak | -5~+105 cmH2O |
Pmean | -5~+105 cmH2O |
Pplat | -5~+105 cmH2O |
PEEP | 0~40 cmH2O |
Ptracheal | -10~110 cmH2O |
Poutput | -10~110 cmH2O |
Pambient | 0-3000 cmH2O |
P0:1 | -105~5 cmH2O |
VTe mand | 0~2500 ml |
VTe spon | 0~2500 ml |
VTi mand | 0~2500 ml |
VTi spon | 0~2500 ml |
MVe | 0~100L/min |
MVe spon | 0~100L/min |
MVi mand | 0~100L/min |
MVi spon | 0~100L/min |
Tinsp | 0~100s |
Texp | 0~100s |
PIF | 0~200L/min |
PEF | -200~0L/min |
Vt Leak | 0~5000mL |
Rtotal | 0~250bpm |
Alarm setting | |
Tidal volume | High: 5~5000ml(adult), 5~1000ml(pediatric), 5~500ml(neonatal) Low: 0~4999ml (adult), 0~999ml(pediatric), 0~499ml(neonatal) |
Minute volume | High: 0.2~100L/min (adult), 0.2~60L/min (pediatric), 0.2~40L/min (neonatal) Low: 0.1~99.9L/min (adult), 0.1~59.9 L/min (pediatric), 0.1~39.9 L/min (neonatal) |
Paw | High: 0~98cmH2O(adult), 0~98cmH2O (pediatric), 0~98cmH2O (neonatal) Low: -4~97cmH2O(adult), -4~97cmH2O (pediatric), -4~97cmH2O (neonatal) |
Frequency | High: 1~150bpm(adult), 1~150bpm (pediatric), 1~150bpm (neonatal) Low: 0~149bpm(adult), 0~149bpm (pediatric), 0~149bpm (neonatal) |
FiO2 | High: 19~100%(adult), 19~100% (pediatric), 19~100% (neonatal) High: 18~99%(adult), 18~99% (pediatric), 18~99% (neonatal) |
Tapnea | High: 15~60s (adult), 15~60s (pediatric), 15~60s (neonatal) |
O2 therapy | |
Controlled parameters | 21~100% (increments of 1%), Flow: 0~50L/min |
Controlled accuracy | ± (3vol.%+1% of setting flow: ±(2L/min+10%of setting)(BTPS) |
Trend & Record | |
Type | Tabular, graphic |
Length | 24 hours |
Content | Monitor parameters |
Event log | 5000 |
Environmental Specifications | |
Temperature | Operating: 5~40ºC, storage and transport: -20~60ºC (O2 sensor: -20~50ºC) |
Relative humidity | Operating: 10~95%, storage and transport: 10~95% |
Barometric pressure | Operating: 62~106kPa, storage and transport: 50~106kPa |
Gas supply | |
Gas supply | Medical-grade Oxygen |
Pipe connector | NIST or DISS |
Gas supply pressure | 280~600kPa |
Low pressure oxygen inlet | |
Pressure range | Less than 100 kPa |
Maximum flow | 15 L/min (STPD) |
connector | CPC quick connector |
Power & battery backup | |
External AC power supply input voltage | 100~240V |
Input frequency | 50/60Hz |
Overcurrent protection | 10±5%A |
Fuse | T10AH/250V |
Number of batteries | Two |
Battery type | Built-in Lithium-ion battery, 14.8V DC, 5200mAh |
Battery running time | 6 hours (2 Qty battery) |
Communication interface | |
Communication interface | RJ45, RS232, USB, Nurse call, CO2 Module Connector, SPO2 Module Connector |
O2 therapy | Screen-lock |
Nebulization | Sigh |
Manual breath | SPO2 |
Inspiratory hold | CO2 |
Expiratory hold | RSB |
PEEPi | Compliance |
P0.1 | Calibrate |
ATC | O2 suction |
Packing detail | |
Packing dimension | 748*625*1465 mm/pallet |
G.W. | 55KG |