| Customization: | Available |
|---|---|
| Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
| Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Name | Multi-parameter Patient Monitor |
Model | NL070401001A-4 |
| Place of Origin | CHINA | Certificate | CE ISO |
| Standard Configuration | SpO2, NIBP ,TEMP,pulse rate | Optional Configuration | Independent SpO2 module, Nellcor SpO2 optional |
| Power Source | Electricity | Material | Plastic, ABS+PC Fireproof Materials |
| After-sale Service | Online technical support | Color LCD Display |
8-inch real color TFT screen |
| Power consumption | 100V-240V~,1.0-0.5A | Warranty | 1 Year |
| Instrument Classification | Class II | Customization | Yes |
| Application Range | Adult/Pediatric/Neonatal | Battery | 11.1V24wh Li-ion battery |
| Display | 8"real color TFT screen | 2h operating after full charge | |
| Resolution 800*600 | 5min operating after low battery alarm | ||
| One alarm indicator | Dimension and Weight | 164mm*270mm*128mm; 2.5kg | |
| One working indicator | Package | 360m*250m*290m; 4kg | |
| One battery charge state indicator | Data Storage | ||
| Operating environment | Trend diagram/table | 720h | |
| Temperature | 0~40ºC | NIBP review | 1000 group |
| Humidity | 15%~80% | Wave review | 12h |
| Pressure | 86.0kPa~106.0kPa | Alarm review | 200 alarm events |
| Power Requirements | Quality Standard | CE, ISO 13485 | |
| AC | 100~240V, 50Hz/60Hz | SFDA | Class II B |
| DC | Built-in rechargeable battery | SpO2/NIBP | BF |
| NIBP | Max Standard Deviation | 8mmHg | |
| Method | Oscillometry | Overpressure protection | |
| Measure mode | Manual, Auto, STAT | Adult | 300mmHg |
| Measure interval in auto mode | 1~5/10/15/30/60/90/120/180/240/480min | Pediatric | 240mmHg |
| Measure period in STAT mode | 5min | Neonatal | 150mmHg |
| Pulse rate range | 40~240bpm | SpO2 | |
| Measure & alarm range | Measurement range | 0~100% | |
| Adult: | SYS 40~280mmHg | Resolution | 1% |
| DIA 10~220mmHg | Accuracy | 70%~100%±2% | |
| 40%~69%±3% | |||
| MEAN 20~240mmHg | Pulse Rate | ||
| Pediatric | SYS 40~220mmHg | Measure/alarm range | 20~300bpm |
| DIA 10~160mmHg | Resolution | 1bpm | |
| MEAN 20~170mmHg | Accuracy | ±3bpm | |
| Neonatal | SYS 40~135mmHg | NIBP cuff & tube | |
| DIA 10~100mmHg | Standard accessories | SpO2 sensor | |
| MEAN 20~110mmHg | Lithium-ion battery | ||
| Static pressure measurement | Power cable | ||
| Range | 0~300mmHg | Operator's manual | |
| Accuracy | ±3mmHg | Optional accessories | Nellcor SpO2 |
| Resolution | 1mmHg Accuracy | Suntech NIBP | |
| MAX Mean Error | ±5mmHg | ||
1. 8-inch real color TFT screen.