| Customization: | Available |
|---|---|
| Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
| Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Name | Multi-parameter Patient Monitor |
Model | NL070401001A-5 |
| Place of Origin | CHINA | Certificate | CE ISO |
| Standard Configuration | SpO2, PR, NIBP, ECG, RESP, TEMP | Optional Configuration | Nellcor SpO2, Masimo SpO2, Dual IBP, ETCO2, Touch screen, Thermal printer NELLCOR |
| Power Source | Electricity | Material | Plastic, ABS+PC Fireproof Materials |
| After-sale Service | Online technical support | Color LCD Display |
12.1 inch high resolution color TFT LCD display
|
| Power consumption | 100V-240V~,1.0-0.5A | Warranty | 1 Year |
| Instrument Classification | Class II | Customization | Yes |
| Application Range | Adult/Pediatric/Neonatal | Dimension and Weight | 305mm*160mm*287mm; 3.8kg |
| Display | 12.1" real color TFT screen | Package | 380m*350m*300m; 6.1kg |
| Operating environment | Data Storage | Trend diagram/table: 7*24h | |
| Temperature | 0~40ºC | NIBP review | 400 events |
| Humidity | ≤85% | Wave review | 100min |
| Altitude | -500~4600m | Alarm review | 100 alarm events |
| Power Requirements | Quality Standard | CE, ISO 13485 | |
| AC | 100~240V, 50Hz/60Hz | SFDA | Class II B |
| DC | Built-in rechargeable battery | Anti-electroshock degree | Class I equipment |
| Battery | 4000mA 11.1V lithium battery | Internal power supply | |
| 2h operating after full charge | TEMP/SpO2/NIBP | BF | |
| 5min operating after low battery alarm | ECG/RESP | CF | |
| ECG | SpO2 | ||
| 5 Leads | RA, LA, LL, RL, V | Measurement range | 0~100% |
| Lead mode | I, II, III, AVR, AVL, AVF, V | Resolution | 1% |
| Increase | X250, x500, x1000, x2000 | Accuracy | 70%~100%±2% |
| 0%~69%± no definition given | |||
| Sensitivity | >200μV P-P | Pulse Rate | |
| Input Impedance | >5M | Measure/alarm range | 20~300bpm |
| Bandwidth | Surgery 1~20Hz | Resolution | 1bpm |
| Monitor 0.5~40Hz | Accuracy | ±3bpm | |
| Diagnostic 0.05~130Hz | RESP | ||
| CMRR | ≥100dB | Method | Impedance between RA-ALL |
| Polarization Voltage | ±300mV | RESP impedance range | 0.3~3Ω |
| Baseline Recovering Time | After defibrillation< 3seconds | Base Impedance range | 200Ω~4000Ω |
| Signal Range | 8mV (Peak-to-peak value) | Bandwidth | 0.1~2.5Hz |
| Calibration Voltage | 1mV±5% | RESP rate | |
| ST Segment | Adult | 0~120BrPM | |
| ST Segment Range | -2.0mV~+2.0mV | Neonatal/Pediatric | 0~150BrPM |
| Accuracy | 0.02mV | Resolution | 1BrPM |
| NIBP | Precision | ±2BrPM | |
| Method | Pulse wave Oscillometry | Asphyxia Alarm | 10-40s |
| Measure mode | Manual, Auto, STAT | Standard accessories | NIBP cuff & tube |
| Measure interval in auto mode | 1~5/10/15/30/60/90/120/180/240/480min | ECG cable & electrodes | |
| Measure period in STAT mode | 5min | SpO2 sensor | |
| Pulse rate range | 40~240bpm | TEMP probe | |
| Measure & alarm range | Lithium-ion battery | ||
| Adult | SYS 40~270mmHg | Power cable | |
| DIA 10~215mmHg | Operator's manual | ||
| MEAN 20~235mmHg | Optional accessories | CO2 module | |
| Pediatric | SYS 40~200mmHg | IBP module | |
| DIA 10~150mmHg | Touch screen | ||
| MEAN 20~165mmHg | Trolley bracket | ||
| Neonatal | SYS 40~135mmHg | Hanging bracket | |
| DIA 10~100mmHg | Monitor recorder | ||
| MEAN 20~110mmHg | |||
| Static pressure measurement | 0~300mmHg, ±3mmHg | ||